Instek GPS-810 Spectrum Analyzer

 

 

GSP-810
(150kHz ~ 1000MHz)

 

 

FEATURES:

Frequency Range : 150kHz ~ 1000MHz

Fully Digital Phase Locked Loop Technique Design

High Frequency Stability : ±10ppm

High Resolution of Span to Measure the more detailed signal : 
    Zero,  2kHz ~ 100MHz /DIV 

RBW : 3k, 30k, 220k, 4M

High Input Protection Level : +30dBm, ±25VDC

Reference Level Range : -30dBm ~ +20dBm

Good Noise Floor Performance : -95dBm @30kHz, -100dBm typical ;
    over -150dBm/Hz typical @220kHz and 4MHz RBW 

Spurious Noise : < -60dB

Inter-modulation (3rd) : < -70dBc

Two Markers for Absolute and Relative Measurement

Functions : Max. Hold, Average (2 ~ 32 traces), Freeze, Peak Search, Marker to Center Function 

9 Memories of Save/Recall

RS-232 Interface and Display Software to get Trace from GSP-810 to PC

Options :Power Meter, Tracking Generator, Remote Control Software
 

 

Data Sheet
User Manual
Softwares
      SPECIFICATIONS  

     
FREQUENCY
      Frequency Range 150kHz ~ 1000MHz
      Frequency Resolution 1kHz C.F. entry, 40Hz Sweep resolution at 2kHz/DIV
      Frequency Display 6 1/2 digit setting
      Frequency Control Digital phase locked
      Frequency Stability ±2ppm/year aging,±10ppm, 0 to 50°C
      Frequency Spans Zero, 2kHz to 100MHz/DIV, in a 1-2-5 sequence

      BANDWIDTH
      Resolution Bandwidths 3kHz,30kHz, 220kHz, 4MHz
      Resolution BW Accuracy 15%
      Video Bandwidth 1.6kHz/90kHz coupled with RBW

      AMPLITUDE
      Reference Level Range -30dBm to +20dBm
      Reference Level Accuracy ±1dB at 80MHz
      Input Level Range -100dBm to +20dBm
      Noise Floor -95dBm@30kHz RBW, -100dBm typical/-75dBm:150kHz ~ 10MHz
      Amplitude Display Range 75dB
      Amplitude Accuracy ±1.5dB typical@0dBm, 80MHz
      Amplitude Level Linearity ±1.5dB over 70dB
      Ref. Level Freq. Flatness ±1.5dB over 100MHz, ±2.5dB typical over entire band/±3dB:150kHz ~10MHz
      Harmonic Spur Response <-40dBc, RF input < selected reference
      Non-Harmonic Spur Response <-60dBc typical down from reference level, average, 5MHz/div
      Intermodulation(3rd) <-70dBc, @-40dBm input, 2 tones, 2MHz apart/<-45dBc:150kHz ~10MHz
      Phase Noise -77dBc/Hz at 1GHz, 30kHz offset

      INPUT
      Input Overload Protection +30dBm continuous, ±25VDC
      Impedance 50 ohm nominal
      Return Loss <16 dBRL (VSWR < 1.35)
      Input Attenuation 50dB to 0dB in 10 dB steps coupled to reference level
      Connector Type N female

      MARKER
      Number of Markers 2
      Marker Resolution 0.1dB, 1kHz
      Marker Mode Absolute, Relative, PK -> Marker, Marker -> Center
      Marker Accuracy 0.1dB±amplitude accuracy

      FUNCTIONS
      Memory 9 memories of save/recall
      Trace Max. Hold, Average(2 ~ 32 traces), Freeze (Hold)
      Setup Access parameters

      FM/AM DEMODULATOR
      WB FM 120kHz deviation
      MB FM 75kHz deviation
      NB FM 30kHz deviation
      AM Outputs Internal speaker, 3.5mm stereo jack, wired for mono operation

      REMOTE DISPLAY SOFTWARE & RS-232
      Connecting to PC and getting trace from GSP-810, software will be downloaded from here

      GENERAL
      Power Source 100/120/220/230V AC±10%, 50/60Hz
      Accessory Operation manual x 1
      Dimensions and Weight 310(W) x 150(H) x 455(D)mm, approx. 8.5kg

      OPTIONS
     
     
TRACKING GENERATOR (OPTION 01)
      Frequency Range 10MHz to 1000MHz
      Amplitude Range 0 to -50dBm
      Amplitude Resolution 1dB
      Amplitude Accuracy ±1dB@0dBm, 80MHz
      Attenuation Accuracy ±1dB@, 50MHz
      Amplitude Flatness ±1dB@, 10MHz/DIV, ±1.5dB@0dB,entire band
      Harmonics <-30dBc
      Reverse Power <+30dBm
      Impedance 50 ohm nominal
      Return Loss <10 dBRL (VSWR<2)
      Connector Type N female

      POWER METER (OPTION 02)
      Frequency Range 10MHz to 2GHz, usable to 2.7GHz
      Power Level Range -20dBm to +23dBm, usable to +30dBm
      Power Level Overload +40dBm<10% duty cycle, <10mS duration
      Return Loss <1:1.35 VSWR into 50 ohms, <1:1.25 typical
      Readout Resolution 0.2mW, 100mW scale, 2µW, 1mW scale; 0.1dB, Log scale
      Accuracy ±(10% rdg ±1digit)
      Readout mW or dBm

      REMOTE CONTROL SOFTWARE (OPTION 03)
      Connecting PC to get trace and provide the control for setting